13. Troubleshooting Guide
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
Ice maker is unplugged Plug ice maker in.
Breaker tripped
Reset breaker - if it happens again, call an authorized service
center.
Switch turned to “OFF” Turn switch to “ICE”.
Storage bin is full, keeping ice
maker off
Level of ice has reached sensor tube – it is normal for ice maker to
be off.
Ice maker in a room below 50(10) – room must be warmer for
ice maker to operate.
Drain pipe blocked
(Drain pump model)
Clean the interior of drain pipe.
Ice maker does not
operate
Drain pump not operative
(Drain pump model)
Check the drain pump.
Call an authorized service center.
Ice cubes are too large Cube size control is set too cold Call an authorized service center.
Not enough water
Check water supply – filter may be restricted.
Check inlet water valve – inlet screen may be restricted.
Ice cubes are too small
Cube size control set too warm Call an authorized service center.
Ice cubes are partially
formed – ragged sides
Spray jets may be partially
clogged
Activate wash cycle (See page 19).
Storage bin should fill with ice
and ice maker should shut off in
12~16 hours – if not, condenser
may be dirty
Clean condenser.
Storage bin drain may be
partially restricted
Clean out drain, check installation.
Ice maker makes ice,
but storage bin does
not fill with ice
Air flow to ice maker may be
obstructed
Check installation – kick plate/grill must be free of obstructions.
Ice cubes are partially
formed – white at the
bottom
Not enough water in reservoir
Check water supply – filter may be restricted.
Check inlet water valve – inlet screen may be restricted.
Check for water leak in reservoir.
Ice may be stuck in the
evaporator and the unit is “frozen
up”
Check water supply – filter may be restricted.
Check inlet water valve – inlet screen may be restricted or valve
does not operate.
Hot gas valve may not operate – check and repair or replace.
Too much heat load Inlet water valve leaks through, must be replaced.
No water spray
Water pump does not operate, must be replaced or check for water
leak in reservoir.
No airflow
Fan motor does not operate or fan blade is broken, must be
replaced.
Condenser is completely blocked, must be cleaned.
Compressor does not operate
properly or at all
Call an authorized service center.
Not enough refrigerant Call an authorized service center.
Unit operates but no
ice falling into storage
bin
Hot gas valve leaks through Call an authorized service center.